Nine core braking cable UIC-V 541-5

Construction

FRNC, LSOH, LSFROH, with operation of at least 120 min. in case of fire

VK-UIC 541-V-5

VK-UIC-V 541-5

  1. 4 core, cross – section 10 mm2, marked 1 až 4, insulation thickness 1 mm
  2. 2 core, cross – section 6 mm2, marked A a B, insulation thickness 0,8 mm
  3. 1 core, cross – section 2,5 mm2 , marked D, insulation thickness 0,6 mm
  4. screened 1-pairs cable with conductor cross – section 0,75 mm2, marked X (white) and Y (black)
  5. filling element
  6. jacket, flame retardant non-halogen polymer base, max. diameter 33,5 mm

Technical parameters

A. Elektrical parameters according to UIC 895, UIC 558 Core
(4×10) (2×6) (1×2,5) X-Y (1×2)
A. 1 Conductor resistance at 20°C max. 1,91 Ω/km max. 3,30 Ω/km max. 7,98 Ω/km max. 26,00 Ω/km
A. 2 Insulation resistance at 20°C min. 100 MΩ/km
A. 3 Test voltage 1500 V, 50Hz, 1min
A. 4 Capacity (1MHz) X-Y
Capacity (1MHz) X-S, Y-S
max. 65pF/m
max. 120pF/m
A. 5 Wave impedance 120±12 Ω
A. 6 Transfer impedance max. 0,03 Ω/m
A. 7 Attenuation (1MHz)
Attenuation (2MHz)
max. 12dB/km
max. 14dB/km
B. Design parameters according to UIC 558 Core Cable
(4×10) (2×6) (1×2,5) X-Y (1×2)
B. 1 Conductor cross section 10 mm2 6 mm2 2,5 mm2 0,75 ± 0,05 mm2
B. 2 Number of wires in string min. 19
B. 3 Number of twist min. 12/m min. 10/m

Supply, packing and storage

Cables are delivered in production lengths on wooden or metallic drums. Shorter lengths may be delivered also wound to coils. Cables may be stored at open-air area or in storerooms. They don’t may be exposed to thermal radiation and stored together with flammable liquids or solvents or with products containing these materials. Manipulation with cables is safe in temperature range of -15°C to +70°C and operation temperature for storage is -25°C (short term -40°C) to +90°C.

VK-UIC-V 541-5

V tejto kategórii

Nine core braking cable UIC 541-5
 

Construction 4 core, cross – section 10 mm2, marked 1 až 4, insulation thickness 1 mm 2 core, cross –…

Eighteen core cable VK-UIC 4 x 4 x 1 + 1 x 2 x 0,75
 

Flexible cable for lined remote control and information in passenger carriage RIC. Application FRNC Application 18 core cables VK-UIC 4…

Sixteen core cable VK-UIC 4 x 4 x 1
 

Cable for lined remote control and information in passenger railway carriage RIC Version FRNC Application Cables VK-UIC 4 x 4…

Twin core cable VK-UIC 1 x 2 x 0,75
 

Cable for lined remote control and information in person rail car RIC Version FRNC Application Cable VK-UIC 1 x 2…