Twin core cable VK-UIC-V- 1 x 2 x 0,75

Screened double conductor for lined remote control and information in person rail car RIC

Version

FRNC, LSOH, LSFROH, operation min. 120 min. during fire.

Certificates

EN60332-1-2.2004; EN50268-1.1999; EN50266-2-4.2001; EN50200.2006

Application

Cable VK-UIC 1 x 2 x 0,75 – a typical application is a comunications system in a railway rolling buses and other vehicles. . It is determined for conection link betwen vehicles RIC.Cable corresponding with UIC codex 558 version 2.3.

Construction

VK-UIC-V 1 x 2 x 0,75

VK-UIC-V 1 x 2 x 0,75

  1. Tinned or silver-plated Cu string
  2. EPR isolation, non-halogen polymer base
  3. Layer PET foils
  4. Braiding pair
  5. Layer PET foils
  6. Filler EPR element, non-halogen polymer base
  7. Sheath from TPE flame retardant non-halogen polymer base

X-Y: Twisted cable pair

Marking core in cable:

Core Marking
X white
Y black

Technical parameters

A. Electrical parameters Core
X – Y (1 x 2)
A. 1 Conductor resistance at 20 °C max. 0,026 Ω/m
A. 2 Insulation resistance at 20 °C min. 100 MΩ/km
A. 3 Test voltage 1 500V, 50 Hz, 15 sek.
A. 4 Capacity (1 MHz) X-Y
Capacity(1 MHz) X-S, Y-S
max. 65 pF/m
max. 120 pF/m
A. 5 Wave impedance 120 ± 12 Ω
A. 6 Transfer impedance max. 0,03 Ω/m
A. 7 Attenuation(1MHz)
Attenuation(2MHz)
max. 12 dB/km
max. 14 dB/km
B. Mechanical parameters
B. 1 Conductor cross section 0,75 ± 0,05 mm2
B. 2 Number of wires in string min. 19
B. 3 Number of twist min. 12/m
B. 4 Density braid min. 90 %

Supply, packing and storage

Cables are delivered in production lengths on wooden or metallic drums. Shorter lengths may be delivered also wound to coils. Any lenght has to be accompanied by a label showing:

  • producer’s mark
  • cable type
  • production date
  • cable lenght in meters
  • inspection seal
  • reference to the corresponding standard

Cables may be stored at open-air area or in storerooms. They don’t may be exposed to thermal radiation and stored together with flammable liquids or solvents or with products containing these materials. Manipulation with cables is safe in temperature range of -15°C to + 70°C and operation temperature for storage is –40°C to +90°C.

V tejto kategórii

Nine core braking cable UIC 541-5
 

Construction 4 core, cross – section 10 mm2, marked 1 až 4, insulation thickness 1 mm 2 core, cross –…

Eighteen core cable VK-UIC 4 x 4 x 1 + 1 x 2 x 0,75
 

Flexible cable for lined remote control and information in passenger carriage RIC. Application FRNC Application 18 core cables VK-UIC 4…

Sixteen core cable VK-UIC 4 x 4 x 1
 

Cable for lined remote control and information in passenger railway carriage RIC Version FRNC Application Cables VK-UIC 4 x 4…

Twin core cable VK-UIC 1 x 2 x 0,75
 

Cable for lined remote control and information in person rail car RIC Version FRNC Application Cable VK-UIC 1 x 2…